Reinstating an old fireplace can be an ‘easy win’ when it comes to adding value as part of a renovation project. Few improvements are guaranteed to boost buyer appeal to the same extent.

With a bit of luck, opening up a redundant fireplace might involve little more than prising off a sheet of old hardboard to reveal a hidden gem. But even if you don’t find a long-forgotten marble masterpiece behind, there’s still plenty you can do to create a captivating feature; much will depend on the age of the property and the overall style you’re aiming to create. A large inglenook might be perfect for a woodburning stove, for example.

Shop fireplaces for your project

Chimney breasts, however, take up a fair amount of space. So in smaller houses with cramped layouts it can be tempting to remove a redundant one, perhaps towards the rear of the property in a kitchen or bathroom. However, where a previous owner has already taken out a chimney breast and you want to reinstate the fireplace, it should be possible to rebuild it without breaking the budget (assuming the stack is still in place).

Alternatively, it might be simpler to install an appliance designed to operate via a flue driven through an outside wall.

The Quick Read

  • Many tasks such as installing a new appliance, adding a hearth, as well as structural tasks such as removing chimney breasts, need to comply with Building Regulations
  • Lining a chimney is typically essential before inserting a new appliance or running an open fire
  • Smoke being blown back into the room, or ‘downdraught’, is one common problem, and could be the result of the flue being too cold, or being of inadequate height or overshadowed by high buildings or trees

What Permissions do you Need to Reinstate Fireplaces?

When it comes to getting planning consent, unless the building is listed, you shouldn’t normally need to worry.

However, because of the potential risks from fire and toxic fumes, even if you’re only installing a stove in an existing fireplace or lining a flue, the work will need to comply with Building Regulations (Part J deals with combustion appliances). And, any structural alterations, such as removal of a chimney breast, will also need to comply.

Opening up an Old Fireplace

Before getting down to work it’s advisable to play safe and cover everything in sight because there is a potential that astounding volumes of soot and dust will be generated — engulfing nearby furnishings, persons and pets in a thick, black miasma.

It’s also worth bearing in mind too that the vibration from builders’ Kango breakers can be very effective at rearranging the neighbour’s ornaments on the other side of a party wall. So a bolster and club hammer is probably a better option for localised demolition where old fireplaces have been bricked up. Having exposed the original ‘builder’s opening’, large deposits of accumulated soot and rubble will likely need to be removed before the chimney can be swept and the flue lined.

In most properties built in the 19th and early 20th centuries, the opening will be spanned by a load-bearing brick arch supported on a curved steel former. Exposed brickwork can look very appealing, but if the size of the opening needs to be altered, a concrete lintel can be inserted and the masonry plastered over.

Whatever your taste in fires, once you have a clean opening and a freshly swept flue, the next job is normally to upgrade the hearth, traditionally made from concrete set flush into the floor void. To comply with Building Regulations this will need to be raised above floor level; it’s a simple job to form a new one directly on top from in-situ concrete, or you might opt for a marble or slate hearth.

The new fire surround will stand on top of the hearth, screwed to the wall via small side lugs which can be inset into the wall and plastered over. Finally, if your preference is for a traditional Victorian cast iron insert, this can now be positioned centrally, secured by a mass of weak concrete placed behind it.


Supporting the opening where a fireplace used to be

Opening up an existing fireplace can be dusty and dirty work — with years of soot and dust being released in to the house; covering furnishings is certainly advisable. Rubble will need to be removed before the chimney can be swept and lined

Rebuilding an old fireplace

Air Supply and Appliances

The provision of a sufficient amount of oxygen, both for occupants and for the combustion of fires or appliances is a key part of compliance with current Building Regulations. This might require vents to be fitted close to the fire.

In timber floors, vents can be inserted into the floorboards so that the fire draws air from under the floor (rather than creating a draught under the living room door), which has the beneficial side effect of enhancing subfloor ventilation. Alternatively, vents are sometimes placed on outside walls just above the skirting. Redundant flues also need to be ventilated to prevent staining to chimney breasts caused by moist air condensing within the flue.

If required, a new gas supply can be piped to the fireplace under a timber floor or via copper pipe (usually 22mm) run externally and clipped to the outside wall surface. But when it comes to the installation of gas appliances, by law this task must only be carried out by a Gas Safe-registered engineer.

As ‘competent persons’, approved installers can ‘self-certify’ that work has been carried out in compliance with Building Regulations and issue completion certificates. HETAS is the equivalent body for solid fuel-burning appliances.

The Importance of the Flue

Enclosed by the chimney breast and stack masonry, flues are designed to safely disperse smoke and combustion gases. Often multiple flues are accommodated within a single chimney with thin internal partitions. Before a fire can be used, in most cases the flue will need to be lined. In older properties, flues were lime rendered internally (known as ‘parging’), but over the years this can come loose and mortar joints can erode, allowing smoke and fumes to emerge in an adjacent flue or room.

Lining typically involves inserting a flexible steel tube down from the top — a job which can require scaffolding, adding to the cost of the task. The type and diameter of the flue liner, and the cowl or terminal, are both specific to individual appliances and fires and are specified by the manufacturer and/or installer.

Removing Old Chimneys Breasts

If a disused chimney breast needs to be removed, it’s essential that the remaining masonry in the room or the roof space above is properly supported. This is best achieved with a steel beam, although in some cases Building Control may accept metal ‘gallows brackets’ and a suitable lintel.

The remaining defunct flue above will also need to be capped and vented so that rain or condensation doesn’t drip down onto the ceiling. Aesthetically it’s important to conceal the evidence that a chimney breast has been removed. This will require some nifty plastering and decoration to the wall, as well as matching in a new ceiling and coving, and replacing skirting and the floor coverings.

Where structural alterations have been carried out in the past without Building Regulations consent, it can cause major problems upon resale, since a certificate is required to prove that the work was done competently. The best course of action here is to make an application to Building Control for a ‘regularisation certificate’ (in effect you’re applying for retrospective consent), but this usually necessitates a certain amount of opening up to inspect the structure.

Damp Chimney Breasts

Unsightly damp patches and staining to walls, chimney breasts, and fireplaces are signs of underlying problems. The two main causes of damp (other than leaks at roof flashings) are rainwater coming down chimney pots and condensation.

Burning fuel produces water vapour which turns to moisture when it hits cold surfaces, especially if the stack is particularly tall or located on a cold outer wall. Fuels such as freshly cut timber are particularly wet and give off a lot of water vapour. Once mixed with soot the moisture can bleed through the plasterwork leaving ugly stains.

In older properties, the stack walls were built without a damp-proof course (DPC), and eroded mortar joints can allow damp to penetrate down through porous masonry. To prevent this, modern stacks have a DPC through the chimney at approximately 150mm above the roof and another near the head.

Condensation inside the stack can usually be resolved by installing a suitable flue liner. But this can sometimes lead to problems where pots and flues are exposed to rain, because rather than being absorbed into the masonry, the rainwater may be channelled straight down the ‘chute’ forming puddles in the fireplace.

To exclude the entry of rain there’s a wide variety of caps, cowls, and hoods available to protect pots and flues. Even if redundant fireplaces are sealed up and you don’t want to use them, there should be a flow of air to prevent condensation with pots hooded or capped, and airbricks inserted in the stack wall.

Where damp is seeping down through porous chimney masonry, repointing the brickwork joints can sometimes solve the problem, or new larger flashings can be fitted that extend higher up and deeper into the brickwork.

Smoky Open Fires or Poor Burning

One common problem is smoke that doesn’t go up the chimney but instead blows into the room, or a fire that becomes choked and struggles to burn, choking on exhaust gases that are not fully dispersed.

Fireplaces rely on the principle that warm air rises. A regularly used flue helps keep the escaping smoke warm, aiding its ascendance.

  • Some chimneys are simply too cold to draw well, particularly those on outside walls.
  • A stack that is too short or overshadowed by high buildings or trees can result in a downdraught with the smoke blowing back down.
  • Flues that are too large can cause smokiness because it takes a long time for them to get warm enough to help the smoke rise.
  • Flues that are too small can choke the fire.

Probably the most common cause of smoky fires is a lack of air, particularly in houses where draughts have been sealed up. Smoke can also become trapped because there’s something blocking the flue — indeed anything which obstructs the flow of smoke and combustion gases, such as a badly fitted pot, can be a problem. Although there are multiple possible causes of smoky fires, sometimes the problem can even be down to a temporary change in wind direction distorting air pressure.

Remedies

  • Air starvation can be cured by boosting air supply by installing (closable) vents or an underfloor grille near the fire.
  • Flues that are too large can be modified with a suitable flue liner, and a ‘throat restrictor’ can be fitted to narrow the entry zone from the fireplace.
  • Smoke will disperse more efficiently where internal flue walls are smooth, once lined.
  • To clear blockages – debris, soot, nests, etc. – ensure that the chimney has been swept.
  • To solve downdraughts, a special draught-inducing cowl or circular deflector can be fitted, or the height of the flue raised with a pot extender.

Smoke and Fumes Leaking into Other Rooms

A blocked flue can divert smoke and fumes into adjoining rooms or adjacent flues. Smoke leakage and fumes may cause drowsiness, and there are potentially very serious dangers from breathing in poisonous fumes and from the risk of fire. Gas or oil-fired appliances are particularly prone to producing deadly, odourless carbon monoxide, too.

Look for signs of bird ingress and blockage such as feathers, sticks, straw and large amounts of soot in the grate. To prevent blockages caused by bird access and nests, unprotected chimney pots can be fitted with bird guards.

Gas and oil appliances need special chimney-top terminals to prevent blockage and to help disperse gases, too.

Gaps may have also formed where mortar joints have been eroded over time by acidic chemicals from combustion gases. Leaks can sometimes go undetected, particularly within lofts or to adjoining houses. The airtightness of a flue can be tested using smoke pellets (available from DIY stores). Where possible, leaky mortar joints should be made good prior to lining the flue. But even where a flue is already lined, old steel liners eventually suffer from corrosion.

It’s essential that flue liners are of the right type for the fire or appliance. Flexible single-skinned liners are used mainly for gas fires and oil or gas-fired boilers, whereas hardier double-skinned liners are required for burning solid fuels (i.e. for woodburners).

Preventing Chimney Fires

Fires in flues can burn unnoticed until structural damage is caused or fire spreads to the main house. Symptoms include excessively hot chimney breasts and the smell of burning.

Over time, soot and tar can build up inside flues and may eventually ignite causing hidden chimney fires that are hard to extinguish. A chimney fire can burn at over 1,000°C, causing metal liners to collapse. This is more common where the fuel being burnt is green, unseasoned timber as it generates excessive tar. But soot deposits can also be a result of inefficient combustion caused by poor air supply.

Flues need to be swept annually to remove combustible soot deposits and blockages. Choose a sweeper who’s National Association of Chimney Sweeps (NACS) or HETAS approved and ideally also a member of the Guild of Master Sweeps.

Wood and peat are particularly aggressive fuels and can produce a rapid build-up of tar and resinous deposits on the inside of the flue. But sweeping flexible flue liners can be difficult, so one trick of the trade is to occasionally burn smokeless fuel in a very hot fire which, it is claimed, melts the deposit away.


Ian RockAbout the Author

Chartered surveyor Ian Rock is director of the survey price comparison website www.Rightsurvey.co.uk and author of the Haynes Period Property Manual.

Image: John Lawrence

Save

Articles like this Featured Products Comments
Comments
  • Jeff Reed

    The only reason I would open it up is to begin the process of demolition. I am now using a bio-ethanol fireplace which allows me to heat my house much more efficiently.

  • Anonymous

    Good article, nice to see fire places making a comeback! You can find such a great range of fire baskets now that there’s really no excuse.

  • Eddie Hewitt

    What are the minimum dimensions for the brick opening,
    To fit the fireback and cheeks into for a standard 16 inch open grate and ashtray.

    Cheers

    Eddie Hewitt

  • Anonymous

    I have opened up my fireplace in a house built in 1972 to find that it is off centre. Does anyone have any ideas as to what we can do with this, ideally I would like it to be centred

    Thanks
    Cheryl, Liverpool

  • sebastien

    It is a very interesting article, but I came across a slight issue.
    While removing the first layer of plaster, I’ve noticed that the opening that has been boarded up is not in the middle of chimney breast.
    What kind of fireplace could have been in the past?
    I hope somebody can clarify this.
    Seb

  • daveyb

    I have got the same thing in my flat. the opening in the chimney breast is approx 500mm wide, on one side there is one brick thick masonry (215mm thick) the other side there is 2 No. half brick masonry forming the flue from the downstairs fireplace (total around 350mm). I wonder if the original fireplace was on one side or if the fireplace wasn’t centered on the opening. I am intending to put a wood burner in so might put a false wall in the opening making it smaller, but meaning that it appears centered on the chimney breast.

  • Qualified HETAS engineer

    The Installation of a Solid Fuel open fireplace or Woodburner is not a DIY project and should always be carried out by a qualified HETAS engineer, as the job has to be certificated and data plated under Building Control Part J, with the local authority Building Control being informed.
    If this is not carried out, then all your Home, Contents and Building Insurances will be invalid.
    Do not tempt fate, get it done by a professional !!!!!!!!!!

  • Anonymous

    Simple job for compatent DIY man got council to sign off work £90 saved £100’s on quote

  • Luke Timms

    Ok, so I have the new lintel in place but opening up either side of the inside of the chimney, it narrows to about 12 inches, am I ok to remove the bricks below this as its been staggered all the way up so wont affect stability? I’m half a brick either side and eagerly holding the club hammer…

    Any advise you give me is just that ‘advice’, I make my own choices based on many opinions, don’t feel guilty for mistakes I make from words you say.

  • Jeremy Olm

    Whenever I am viewing houses, I ensure that it is in the condition that I am looking for. Therefore, if a certain house does not have an existing fireplace, I would simply get my estate agent to scout for others that have a ready one. It will take extra effort and probably even costs to set up a new fireplace by opening it all back up either by DIY method or getting someone to help you out.

  • […] Many period houses will have fireplaces; some may not be in use whereas others may just look old and decrepitated. It is easy to clean a fireplace and bring it back to life with the right tools. Discover how to open up a fireplace. […]

  • Post a comment
    You must be logged in to comment. Log in